Acid Mist Desulphurization Cyclone Flame Retardant Scrubber Waste Gas Treatment Equipment

Product Details
Customization: Available
Application: Environment Friendly
Type: Scrubber Machine
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Fast Delivery
The supplier can deliver the goods within 15 days
ODM Services
The supplier provides ODM services
Production Process Visualization
You can check the supplier's production workflow chart or main facilities in the Audit Report
to see all verified strength labels (19)
  • Acid Mist Desulphurization Cyclone Flame Retardant Scrubber Waste Gas Treatment Equipment
  • Acid Mist Desulphurization Cyclone Flame Retardant Scrubber Waste Gas Treatment Equipment
  • Acid Mist Desulphurization Cyclone Flame Retardant Scrubber Waste Gas Treatment Equipment
  • Acid Mist Desulphurization Cyclone Flame Retardant Scrubber Waste Gas Treatment Equipment
  • Acid Mist Desulphurization Cyclone Flame Retardant Scrubber Waste Gas Treatment Equipment
  • Acid Mist Desulphurization Cyclone Flame Retardant Scrubber Waste Gas Treatment Equipment
Find Similar Products
  • Overview
  • FAQ
Overview

Basic Info.

Environmental Protection
Medical
Main Function
Waste Gases Removal
Transport Package
Wooden Case
Trademark
YUNSHI
Origin
China
HS Code
8424899990

Product Description

Acid Mist Desulphurization Cyclone Flame Retardant Scrubber Waste Gas Treatment EquipmentAcid Mist Desulphurization Cyclone Flame Retardant Scrubber Waste Gas Treatment EquipmentAcid Mist Desulphurization Cyclone Flame Retardant Scrubber Waste Gas Treatment Equipment
PP spray tower operation procedure
First. Preparation before starting the machine
1. Add the water level of the tank and distribution tank to the equipment overflow port and open the inlet valve.
2. Check pump and fan, tighten each bolt in time.
Second, the boot
Turn on the spray pump switch, and turn on the fan switch after the spray runs uniformly. Observe whether the pump and fan are running normally, whether there is leakage, whether there is abnormal sound.
Third, stop
Cut off the fan power, then cut off the spray pump power, clean the site.
Fourthly. Daily maintenance
1. When the water level of the distribution tank falls to 200mm above the water inlet of the pump, the distribution tank must be filled with water immediately to prevent the pump from burning out and the temperature in the tower is too high.
2. The mixed liquid in the tank should be replaced every 7 days and the sludge should be discharged once a month to prevent the sludge from blocking the water inlet hole of the pump.
3. Fill in the equipment operation record for each shift.
TANKS SPECIFICATION LIST
Tank Material
PP: 12/15/20/25mm thickness based on tank size calculation
Stainless steel 304/316
TANK Reinforcement:
Tank with a flat tube [80 × 60 × 4t] reinforcing the circular horizontal 2line, square tube A3 are blasted and rust primer, outer
seal 3mmtPP board.
* The flat tube size is calculated based on tank size
Water inlet system(optional)
Inlet:1″PVC branch pipe,assemble with doule union PVC ball valve
Water drainage system(optional)
PP ball valve with flange fitting or customized
Air agitating piping(optional)
Bath inner part: configuration: 3/4 "PPR arrangement H-shaped pipeline;
Bath outer part: configuration: 3/4 " double union PVC valve
Heating system(optional)
Stainless steel/Titanium/Telflon material
Cooling system(optional)
φ19/φ25/φ32 Stainless steel /Titanium material
 
Acid Mist Desulphurization Cyclone Flame Retardant Scrubber Waste Gas Treatment EquipmentAcid Mist Desulphurization Cyclone Flame Retardant Scrubber Waste Gas Treatment EquipmentAcid Mist Desulphurization Cyclone Flame Retardant Scrubber Waste Gas Treatment EquipmentAcid Mist Desulphurization Cyclone Flame Retardant Scrubber Waste Gas Treatment EquipmentAcid Mist Desulphurization Cyclone Flame Retardant Scrubber Waste Gas Treatment EquipmentAcid Mist Desulphurization Cyclone Flame Retardant Scrubber Waste Gas Treatment EquipmentAcid Mist Desulphurization Cyclone Flame Retardant Scrubber Waste Gas Treatment Equipment
 
FAQ

1. Q: Are you a manufacturer?

A: We are manufacturer. We have been engaged in this field for 18 years.

2. Q: How many years since you have been in this field?

A: We have been engaged in this field for 18 years.We have rich experience for manufacturing and designing the machines.

3. Q: How about your product quality?

A: We have own research and development team, rich experiences technicians, and professional workers. We pay attention to every detail in manufacturing to ensure Product with high quality.

4.Q: What is your MOQ?
MOQ is different according to different kinds of product. But we accept small quantity for trial order. Please contact us for details.

5. Q: What is payment term?

A: T/T 30% deposit and 70% balance before shipment or see the against copy of B/L.

6. Q: How can I contact you?

A: Please look at my contact card. You can talk to me anytime. Or send me enquiry email, I will reply you in 24 hours and
offer the optimum solution to you.

7.Q: How can I get the sample?


If sample without logo,we can offer you free sample, but we need to charge you freight. If sample with logo, please contact with us, we will quote you sample and freight.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.